TK2600 Pulse Voltage Source
TK2600 Pulse Voltage Source

TK2600 Pulse Voltage Source

TK2600 is a high-performance pulsed voltage source designed for precision testing and calibration applications. It can generate pulse voltages up to 2 kV, with fully adjustable pulse amplitude, repetition rate, and pulse width. With a fast rise and fall time of less than 10 μs, the TK2600 delivers rapid step-response performance, making it ideal for high-speed testing scenarios.

The device is equipped with a computer-programmable communication interface, enabling automated control, data logging, and integration into complex testing systems. TK2600 is particularly suitable for measuring the response time of current sensors, Roche coils, and similar devices, as well as for calibrating pulse shunts and high-voltage instrumentation. Its modular and flexible design ensures compatibility with a wide range of industrial, laboratory, and research applications.

Additional features include high voltage stability, precise pulse control, reliable operation under varying environmental conditions, and built-in protection mechanisms to prevent overvoltage and thermal overload. The TK2600 ensures accurate, repeatable, and safe pulsed voltage outputs, making it an essential tool for high-precision electrical testing and calibration.

TK2600 Pulsed Voltage Source Specifications

Parameter Specification
Pulse Type Unipolar pulses, rising edges, and falling edges
Output Range 200 V ~ 2 kV
Adjustment Fineness 0.1 V
Single Pulse Width Adjustable from 1 ms ~ 10 ms
Single Pulse Rise Time ≤ 10 μs
On-Time (Rising/Falling Edge) Adjustable in the range of 10 ms ~ 10 s
Voltage Accuracy ± 0.5% × range

General Specifications

Power Supply AC (220±22) V, (50±2) Hz
Maximum Power Consumption 150 VA
Working Environment Temperature: 15°C ~ 30°C, Humidity: 20% RH ~ 80% RH, non-condensing, no electromagnetic field interference
Storage Environment Temperature: -20°C ~ 70°C, Humidity: <95% RH, non-condensing
Communication Interface RS232 ×1

Note: Specifications are subject to change. Ensure environmental conditions comply with operating requirements for accurate performance.