TI5300 AC DC Current Sensor Testing Device
TI5300 AC DC Current Sensor Testing Device

TI5300 AC DC Current Sensor Testing Device

TI5300 is a high-precision instrument designed for comprehensive testing of current sensors. It integrates AC and DC current standard sources, a sensor output power measurement module, and an auxiliary power supply, providing a complete solution for sensor characterization. The device enables direct measurement of critical sensor parameters, including ratio difference, phase angle difference, power consumption, and linearity. With configurable measurement ranges, high accuracy, and fast response, the TI5300 is ideal for laboratory calibration, industrial sensor testing, and quality assurance applications. Its modular design and user-friendly interface allow flexible operation, precise control, and easy integration with automated testing setups, ensuring reliable and repeatable measurement results for a wide range of sensor types and ratings.

AC and DC Current Standard Sources

Current Range Resolution Frequency (Hz) Short-term Stability (ppm/min) Measurement Uncertainty (k=2)
(ppm*RD + ppm*RG)
Temperature Coefficient (ppm*RG/°C) Compliance Voltage (Vrms)
300 mA 100 nA DC 30 60 + 40 5 2
1 A 1 μA DC 30 60 + 40 5 2
3 A 1 μA DC 30 60 + 40 5 2
10 A 10 μA DC 30 60 + 40 5 2
30 A 10 μA DC 30 60 + 40 5 2
100 A 100 μA DC 30 60 + 40 1.5 0.8

Sensor Secondary Power Measurement

Parameter Specification
Current Range 10 mA, 100 mA, 1 A, manual/automatic switching
Measurement Range: ± (1 mA ~ 1.1 A)
Voltage Range 100 mV, 1 V, 10 V, manual/automatic switching
Measurement Range: ± (10 mV ~ 12 V)
Measurement Frequency DC, AC 45 Hz ~ 1 kHz
Measurement Uncertainty (k=2) DC: 30 + 20 ppm
AC: 60 + 40 ppm
Display Resolution 7-digit decimal

Sensor Power Supply and Power Consumption Measurement

Parameter Specification
Supply Voltage DC ± (5.0 V ~ 50.0 V), adjustable
Maximum Load Capacity 1 A
Measurement Uncertainty (k=2) Voltage / Current: 0.2%, Power: 0.5%
Protective Function Short circuit protection, overload protection, overheating protection

Note: RD = Reading Value, RG = Range Value.