TI5800 Sensor Power Supply and Output Tester
TI5800 Sensor Power Supply and Output Tester

TI5800 Sensor Power Supply and Output Tester

TI5800 integrates a precision voltmeter, precision ammeter, and programmable adjustable voltage source. It supplies power to a voltage or current sensor during testing, ensuring accurate measurement of the sensor's secondary output current (Is) or voltage (Us). This instrument can be combined with a standard current source or voltage source to form a complete sensor testing system for evaluating various voltage or current sensors.

Designed for laboratory, industrial calibration, and manufacturing environments, the TI5800 offers high stability, wide measurement range, and intuitive control operations. Its advanced measurement algorithms improve reading precision, making it suitable for applications requiring high accuracy and repeatable testing results.

With built-in protection mechanisms such as over-voltage, over-current, and short-circuit protection, the TI5800 ensures reliable and safe performance during testing. Its programmable functionality enables automation, data recording, and rapid test execution, significantly enhancing efficiency and consistency in testing workflows.

Technical Specifications

Parameter Specification
DC Current Measurement Range 10 mA, 100 mA, 1 A (manual/automatic switching)
Measurement Scope: ± (1 mA ~ 1.1 A)
DC Voltage Measurement Range 100 mV, 1 V, 10 V (manual/automatic switching)
Measurement Scope: ± (10 mV ~ 12 V)
DC Measurement Uncertainty (k=2) 0.003% × RD + 0.002% × RG
Temperature Coefficient
(0°C ~ 40°C)
≤ 2 ppm × RD / °C
Display Resolution 7-digit decimal

AC Voltage/Current Measurement (Optional)

Parameter Specification
AC Current Measurement Range 10 mA, 100 mA, 1 A (manual/automatic switching)
Measurement Scope: 1 mA ~ 1.1 A
AC Voltage Measurement Range 100 mV, 1 V, 10 V (manual/automatic switching)
Measurement Scope: 10 mV ~ 12 V
Measurement Frequency 45 Hz ~ 1 kHz
AC Measurement Uncertainty (k=2) 0.006% × RD + 0.004% × RG
Temperature Coefficient
(0°C ~ 40°C)
≤ 5 ppm × RD / °C
Display Resolution 7-digit decimal

General Specifications

Parameter Specification
Power Supply AC (220 ± 22)V, (50 ± 2)Hz
Maximum Power Consumption 100 VA
Warm-up Time Up to 30 min (2× predicted warm-up time)
Operating Environment Temperature: 0°C ~ 40°C
Humidity: 20% RH ~ 80% RH (non-condensing)
No strong electromagnetic interference
Storage Environment Temperature: -20°C ~ 70°C
Humidity: < 95% RH (non-condensing)
Altitude < 3000 m
Communication Interface RS232 × 1

Note: RD = Reading Value, RG = Range Value.