High Performance EV Battery Test System
High Performance EV Battery Test System

High Performance EV Battery Test System

High-Performance EV Battery Test System utilizes a full-bridge circuit topology combined with high-resolution digit sampling chips to deliver superior measurement precision and dynamic test data. It is designed to provide comprehensive testing programs for mainstream lithium-ion batteries as well as batteries using alternative chemistries, including sodium-based systems. The system is ideal for research, development, and production environments in electric vehicle and advanced battery manufacturing sectors.

The test system supports multi-channel operation with customizable channel counts, allowing high-current parallel testing while maintaining ±0.02% F.S. measurement accuracy. It offers precise voltage and current control with fast response times, making it suitable for high-speed charge-discharge cycling, DCIR measurement, and EV drive simulation tests. The system also features 10ms high-speed operating condition simulation, supporting extensive data logging with millions of records and Excel import for analysis.

Model Max Power Channels Voltage Range Voltage Accuracy Voltage Resolution Current Range Current Accuracy Current Resolution
BTS-6V400A16CH 38.4 kW 16 -6 V ~ +6 V (expandable to 10 V) ±0.02% F.S. 0.01 mV -400 A ~ +400 A ±0.02% F.S. 0.01 mA
BTS-6V600A8CH 28.8 kW 8 -6 V ~ +6 V (expandable to 10 V) ±0.02% F.S. 0.01 mV -600 A ~ +600 A ±0.02% F.S. 0.01 mA
BTS-6V800A8CH 38.4 kW 8 -6 V ~ +6 V (expandable to 10 V) ±0.02% F.S. 0.01 mV -800 A ~ +800 A ±0.02% F.S. 0.01 mA
BTS-6V1200A4CH 28.8 kW 4 -6 V ~ +6 V (expandable to 10 V) ±0.02% F.S. 0.01 mV -1200 A ~ +1200 A ±0.02% F.S. 0.01 mA
BTS-6V2400A2CH 28.8 kW 2 -6 V ~ +6 V (expandable to 10 V) ±0.02% F.S. 0.01 mV -2400 A ~ +2400 A ±0.02% F.S. 0.01 mA

Charge & Discharge Test Parameters

  • Rise Time: ≤1 ms
  • Switching Time: ≤2 ms
  • Minimum Recording Interval: 1 ms / 0.1 mV / 0.1 mA
  • Operating Modes: CC, CV, CP, CC-CV, CR, DCIR, Pulse, Drive Simulation
  • Drive Simulation: 10 ms operating condition, 10 million+ lines of data, Excel import supported
  • Channel Parallel Operation: Supports up to 6400 A with ±0.02% F.S. accuracy
  • Efficiency: Charge efficiency 75%; regenerative feedback efficiency 73%