High-Volt Storage Battery Cluster Test System
High-Volt Storage Battery Cluster Test System

High-Volt Storage Battery Cluster Test System

1700V PACK test equipment adopts the SINEXCEL-RE advanced high-frequency isolation solution. It features compact size, high efficiency, low heat dissipation, and flexible configuration. The detection process supports multi-gear switching, making it suitable for ESS system detection, ultra-high voltage EV PACK batteries, and other applications. The device can integrate various communication protocols such as temperature box, water cooler, CAN, CANFD, 485, and supports innovative functions like one-click automatic data export to meet all aspects of PACK battery electrical performance testing.

   Parameter Specification
Output Voltage Range 50 V ~ 1700 V
Voltage Accuracy ± 0.03% F.S.
Voltage Resolution 0.1 mV
Output Current Range -200 A ~ +200 A | -400 A ~ +400 A | -600 A ~ +600 A | -1200 A ~ +1200 A
Current Range Options 100 A / 200 A | 200 A / 400 A | 200 A / 400 A / 600 A | 200 A / 400 A / 600 A / 1200 A
Current Accuracy ± 0.03% F.S. (Based on current range)
Current Resolution 0.1 mA
Channels Quantity 2CH / 4CH (Support for customisation)
Total Power 400 kW ~ 1.2 MW (Support for customisation)
Rise Time ≤ 5 ms
Switching Time ≤ 10 ms
Minimum Recording Time 10 ms / 0.1 mV / 1 mA
Charge-Discharge Operation Modes CC, CV, CP, CC-CV, CR, DCIR, Pulse, Drive simulation and other modes
Drive Simulation for EVs 50 ms operating condition, 10 million+ lines of data, supports Excel import
Channel Parallel Supports parallel connection of 6400 A (accuracy after parallel connection ±0.02% F.S.)
Efficiency Charge efficiency: 95.5%; Feedback efficiency: 95.5%