Battery PACK (500v-1000v) Test System
Battery PACK (500v-1000v) Test System

Battery PACK (500v-1000v) Test System

PACK Test Equipment utilizes the SINEXCEL-RE advanced architecture and is based on a three-level AC scheme. The detection process supports multi-gear switching and integrates auxiliary channels for voltage, temperature, and pressure. The system is capable of interfacing with various environmental and communication protocols, including temperature chambers, water coolers, CAN, CANFD, and RS-485, enabling full-spectrum monitoring and control. With practical functions like one-click automatic data export, it delivers comprehensive testing solutions for PACK battery electrical performance evaluation.

The equipment is designed for flexibility, supporting multiple configurable channels to match different battery pack sizes and current requirements. It features high-speed response and precision measurement, making it ideal for complex testing scenarios such as pulse charge/discharge, DCIR, cycle life, and drive simulation for electric vehicles. The system also supports channel parallelization, allowing high-current testing with maintained accuracy, making it suitable for large-scale R&D and production applications.

Advanced safety and reliability features include overcurrent, overvoltage, and reverse connection protection, as well as robust data integrity mechanisms. Real-time monitoring and customizable reporting ensure that testing is repeatable, accurate, and compliant with industrial standards. The high efficiency of charge (95%) and feedback (95%) ensures minimal energy loss during testing, supporting sustainable and cost-effective operation.

This PACK test system is ideal for battery manufacturers, research institutes, universities, and EV production centers requiring high-precision, reliable, and comprehensive testing solutions for modern battery packs.

PACK Test Equipment Specifications

Parameter Specification
Output Voltage Range 10 V ~ 1250 V
Voltage Accuracy ± 0.02% F.S.
Voltage Resolution 0.1 mV
Output Current Range -300 A ~ +300 A | -450 A ~ +450 A | -600 A ~ +600 A | -1200 A ~ +1200 A
Current Range Options 150 A / 300 A | 150 A / 300 A / 450 A | 150 A / 300 A / 450 A / 600 A | 300 A / 600 A / 900 A / 1200 A
Current Accuracy ± 0.02% F.S. (Based on current range)
Current Resolution 0.1 mA
Channels Quantity 2CH / 4CH / 8CH (Support for customisation)
Total Power 300 kW ~ 1.6 MW (Support for customisation)
Rise Time ≤ 5 ms
Switching Time ≤ 10 ms
Minimum Recording Time 10 ms / 1 mV / 1 mA
Charge-Discharge Operation Modes CC, CV, CP, CC-CV, CR, DCIR, Pulse, Drive simulation and other modes
Drive Simulation for EVs 50 ms operating condition, 10 million+ lines of data, supports Excel import
Channel Parallel Supports parallel connection of 6400 A (accuracy after parallel connection ±0.05% F.S.)
Efficiency Charge efficiency: 95%; Feedback efficiency: 95%