UC2869XB-67XB-66XB-78XB Transformer Tester
UC2869XB-67XB-66XB-78XB Transformer Tester

UC2869XB-67XB-66XB-78XB Transformer Tester

The UC2869XB series Comprehensive Transformer Tester is designed for multi-parameter testing of transformers, coils, and windings. It supports measurement of laps ratio, phase, inductance, capacitance, leakage inductance, quality factor, AC/DC resistance, balance, pin short circuit and more, making it ideal for production lines, incoming inspection, and laboratory use.

Available Models & Frequency Range

  • UC2869XB: 20Hz – 200kHz
  • UC2867XB: 20Hz – 300kHz
  • UC2866XB: 20Hz – 500kHz
  • UC2878XB: 20Hz – 1MHz

Performance Characteristics

  • 7-inch 16:9 TFT LCD display, 800 × 480 RGB resolution
  • All test results displayed on a single screen
  • Direct saving of test results via U disk
  • Maximum test frequency up to 1MHz, resolution 10mHz
  • Basic measurement accuracy up to 0.05%
  • Ultra-fast test mode up to 150 times/sec
  • Automatic Level Control (ALC) for voltage or current testing
  • Multiple signal source output impedances: 30Ω, 100Ω, 10/100, 10/CC
  • Built-in comparator with 10 sorting files and counting function
  • 100 internal setting files, unlimited expansion via U disk
  • Optional internal DC bias source: ±10V (±100mA) or 1A
  • Firmware upgrade via USB HOST
  • U disk supports FAT16 and FAT32 file systems
  • Standard interfaces: RS232C, HANDLER, USB HOST
    Optional: GPIB, LAN

Brief Introduction

The UC286XB series adopts a 7-inch high-resolution TFT display for intuitive operation and clear data visualization. With high speed, high precision, and powerful functionality, it meets the stringent requirements of quality assurance, incoming inspection, and R&D laboratory measurements.

General Specifications

Operating Temperature & Humidity 0℃ – 40℃, ≤ 90% RH
Power Supply Voltage 99V – 121V / 198V – 242V AC
Power Frequency 47.5Hz – 63Hz
Power Loss ≤ 80VA
Dimensions (W×H×D) 398 × 129 × 370 mm
Weight Approx. 9 kg

Technical Specifications

Measurement Functions
Transformer Parameters Laps ratio, lap, phase, inductance, capacitance, leakage inductance, quality factor (Q), AC resistance, DC resistance, balance, pin short circuit, LED test
Equivalent Circuit Series, Parallel
Math Functions Absolute deviation, Percentage deviation
Range Method Automatic, Hold, Manual
Trigger Mode Internal, Manual, External, Bus
Measurement Speed (≥1kHz)
  • Ultra-fast: 150 times/sec
  • Fast: 90 times/sec
  • Medium: 12 times/sec
  • Slow: 3 times/sec
Test Signal
Output Impedance 30Ω, 100Ω, 10/100, 10/CC
Signal Level Normal: 5mV – 2V (10% accuracy, 1mV step)
Constant: 10mV – 1V (5% accuracy, 1mV step)
DC Bias Source (Internal) 0V, 1.5V, 2V (Accuracy: 1%)
DC Bias Source (Optional) UC6802A: ±10V (±100mA)
UC6802B: 0 – 1A DC bias current
Display Range
|Z|, R, X 0.01 mΩ – 99.9999 MΩ
DCR 0.01 mΩ – 99.9999 MΩ
Laps Ratio 1:0.001 – 1000:1
|Y|, G, B 0.00001 µS – 99.9999 S
C 0.00001 pF – 9.9999 F
L 0.00001 µH – 9999.99 H
D 0.00001 – 9.9999
Q 0.00001 – 9999.9
θ (DEG) -179.999° – 179.999°
θ (RAD) -3.14159 – 3.14159

Interfaces & Memory

  • Internal memory: 100 groups
  • U disk storage: Unlimited expansion
  • Interfaces: RS232C, HANDLER, USB HOST
    Optional: GPIB, LAN

Standard Accessories

  • UC6801X Scanning Test Box
  • UC26004-1 Four-wire Kelvin Test Cable
  • UC26004B Two-wire Test Cable
  • UC6801-01 Pedal Start Switch
  • UC26016 Scanning Line