UC2836AX-BX-CX Filter Balance Tester
The UC2836 Series Filter Balance Tester is a high-precision, high-speed component measurement instrument designed for testing a wide range of electronic components. The UC2836CX model is a multi-functional component tester capable of accurately measuring Ls, Lp, Q, and DCR, making it ideal for filter testing, inductors, transformers, and precision component analysis.
Model & Frequency Range
- UC2836AX: 20Hz – 30kHz
- UC2836BX: 20Hz – 100kHz
- UC2836CX: 20Hz – 200kHz
Performance Characteristics
- True color 4.3-inch TFT LCD display
- Basic measurement accuracy: 0.1%
- Maximum test speed up to 30 times/sec
- Selectable signal source output impedance: 30Ω, 50Ω, 100Ω
- Built-in 5-grade sorting comparator
- Automatic Level Control (ALC) for voltage/current testing
- 100+ internal setting files, expandable to 500 via U-disk
- Firmware upgrade via USB HOST
- U-disk support with screen copy and FAT16 / FAT32 file systems
- Standard RS232C, HANDLER, USB HOST, USBCDC, USBTMC, headphone interface
- Optional GPIB interface
Brief Introduction
The UC2836CX is a multi-functional component tester designed for accurate and high-speed testing of electronic components. Featuring a 4.3-inch LCD display, low distributed capacitance, and simple operation, it delivers reliable results for high-accuracy filter testing and component analysis in R&D, production lines, and quality control environments.
General Specifications
| Operating Temperature / Humidity | 0°C – 40°C, ≤90% RH |
|---|---|
| Power Supply Voltage | 100 – 120 VAC / 198 – 242 VAC |
| Power Frequency | 47.5Hz – 63Hz |
| Power Consumption | ≤ 30 VA |
| Dimensions (W × H × D) | 380 × 102 × 270 mm |
| Weight | Approx. 3.6 kg |
Technical Specifications
| Specification | UC2836AX | UC2836BX | UC2836CX |
|---|---|---|---|
| Measurement Parameters | Ls, Lp, Q, DCR | ||
| Test Frequency | 20Hz – 30kHz | 20Hz – 100kHz | 20Hz – 200kHz |
| Basic Accuracy | 0.1% | ||
| Double Frequency Test | × | × | √ |
| Equivalent Circuit | Series / Parallel | ||
| Math Functions | Absolute deviation, Percentage deviation | ||
| Range Selection | Automatic / Hold / Manual | ||
| Trigger Mode | Internal / Manual / External / Bus | ||
| Measurement Speed (≥1kHz) | Fast: up to 75 times/sec Medium: 12 times/sec Slow: 3 times/sec |
||
| Average Times | 1 – 255 | ||
| Delay Time | 0 – 60 s (1 ms step) | ||
| Correction | Open / Short / Load | ||
| Test Terminal | Five-terminal | ||
| Display Mode | Direct reading, Δ, Δ%, V/I | ||
| Display | 6-digit resolution, 4.3-inch TFT LCD | ||
| Output Impedance | 30Ω / 50Ω / 100Ω | ||
| Test Signal Level | Normal: 5mV – 2V (±10%, 1mV step) Constant Level: 10mV – 1V (±5%, 1mV step) |
||
| Bias Voltage | 0V / 1.5V / 2V (±1%) | ||
| Display Range | L: 0.0001 µH – 9999.99 H Q: 0.0001 – 9999.9 DCR: 0.001 mΩ – 99.9999 MΩ |
||
| Comparator | PASS / FAIL | ||
| Memory | 100 internal groups + 500 external groups | ||
| Interfaces | RS232C, USB HOST, HANDLER (Optional GPIB) | ||
Standard Accessories
- UC26011B Four-terminal Kelvin test cable
- Power cable
Optional Accessories
- UC26009B SMD Test Pliers
- UC26008A SMD Test Box